CNW-500


CNW-500-12/24

基本参数

额定电压:110/220V

额定输出功率:500W

输出电压:12V/24V

特征

1.保护种类:短路/过负载

2.自然风冷

3.LED电源指示灯

4.100%满载老化

5.空载消耗<0.7W

应用:工业控制或自动化装置、LED灯具系列、老化设备、测试和测量仪器

质保:2

认证:CE、RoHS


Specifications





Product No.NW-500-12NW-500-15NW-500-24NW-500-48

OutputDC voltage12V15V24V48V

Rated Current41A33.3A21A10.4A

Current Range0-41A0-33.3A0-21A0-10.4A

Rated Power500W500W500W500W

Ripple and Noise(Max)Note.2150mVp-p180mVp-p240mVp-p250mVp-p

Voltage adjustment10.8-13.2V13.5-16.5V22-27.6V44-52V

Voltage AccuracyNote3±1%±1%±1%±1%

Linear Adjustment Note4±0.5%±0.5%±0.5%±0.5%

Load AdjustmentNote5±0.5%±0.5%±0.5%±0.5%

Start and rise time1000ms,30ms/230VAC
Hold time(Typ)50ms/230VAC
InputVoltage rangeAC 220±15%
Frequency range50HZ
Efficiency(Typ)80%81%82%82%

AC current(Typ)4.7/220V
Surge current (Typ)Cold Start:65A/230VAC
Current leak<2mA/240VAC
ProtectionOverloadLarger than 105% of capacity
restoration after abnormity removed
Overvoltage





Protection type: Turn off the output voltage and resume after restart
Overheat

EnvironmentWorking temp.-20~+60℃(Refer to the tenuation curve)
Working humidity20~90% RH, without condense
Storage temp & hmdty-40~+80℃
Temp. coefficient±0.03%/℃(0~50℃)
Vibration proof10~500HZ,5G 10min / cycle,X、Y、Z axes 60 min each
Safety reg. & EMC(Note.6)Safety regulationGB195110.1-2004/IEC61347-1:2003CE(EMC+LVD)
Voltage proofI/P-O:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
insulation resistanceI/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH
EMC irradiationEN 55022A:2006;EN61000-3-2:1995+A2:2005
EMC disturbance proofEN 61000-3-2:2006;

Dimensions215*115*50mm(L*W*H)
Packing0.8kg/PCS;24PCS/21.2kg
Notes:1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp.
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate.
4.Linear adjustment: taken under rated load from low voltage to high voltage.
5.Load adjustment: taken under 0~100% of rated load.
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.