CNW-360


CNW-350-12/24

Parameter

Input voltage:110/220Vac

Output power:350W

Output voltage12Vdc/24Vdc

Feature

1. Protection: short-circuit, overload

2. 100% full-load aged

3. Withstand 300VAC surge input for 5 seconds

4. -20+60℃Working temperature

5. 5G vibration tested

6. High efficiency, long life span, and high reliability

Applications: Industrial automation machineryIndustrial control systemTesting and measuring instrumentsHousehold appliances

Led lighting appliancesAging equipmentIT communication equipment

Warranty

2 years

Certificate

CE RoHS


Specifications





Product No.NW-350-3.3NW-350-5NW-350-12NW-350-15NW-350-24NW-350-48
OutputDC voltage3.3V5V12V15V24V48V
Rated Current60A60A30A23.3A15A7.3A
Current Range0-60A0-60A0-30A0-23.3A0-15A0-7.3A
Rated Power198W300W360W350W360W350W
Ripple and Noise(Max)Note.2100mVp-p100mVp-p150mVp-p180mVp-p240mVp-p250mVp-p
Voltage adjustment2.9-3.3v4.8-5.4V10.8-13.2V13.5-16.5V22-27.6V44-52V
Voltage AccuracyNote3±3%±2%±1%±1%±1%±1%
Linear Adjustment Note4±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load AdjustmentNote5±2%1.50%±0.5%±0.5%±0.5%±0.5%
Start and rise time1000ms,30ms/230VAC 1000ms,30ms/110V
Hold time(Typ)50ms/230VAC10ms/115AC
InputVoltage rangeAC 110V±15%/AC 220±15%changed by switch
Frequency range50HZ/60HZ
Efficiency(Typ)70%75%80%81%82%82%
AC current(Typ)6.6A/110V3.3A/220V
Surge current (Typ)Cold Start:65A/230VAC
Current leak<2mA/240VAC
ProtectionOverloadLarger than 105% of capacity
restoration after abnormity removed
Overvoltage





Protection type: Turn off the output voltage and resume after restart
Overheat

EnvironmentWorking temp.-20~+60℃(Refer to the tenuation curve)
Working humidity20~90% RH, without condense
Storage temp & hmdty-40~+80℃
Temp. coefficient±0.03%/℃(0~50℃)
Vibration proof10~500HZ,5G 10min / cycle,X、Y、Z axes 60 min each
Safety reg. & EMC(Note.6)Safety regulationGB195110.1-2004/IEC61347-1:2003CE(EMC+LVD)
Voltage proofI/P-O:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
insulation resistanceI/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH
EMC irradiationEN 55022A:2006;EN61000-3-2:1995+A2:2005
EMC disturbance proofEN 61000-3-2:2006;

Dimensions215*115*50mm(L*W*H)
Packing0.76kg/PCS;24PCS/21.2kg
Notes:1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp.
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate.
4.Linear adjustment: taken under rated load from low voltage to high voltage.
5.Load adjustment: taken under 0~100% of rated load.
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.