DX-36-12/24
Parameter
Input voltage:87-264Vac
Output power:36W
Output voltage:12Vdc/24Vdc
Feature
1. Protection: short-circuit, overload
2. 100% full-load aged
3. Withstand 300VAC surge input for 5 seconds
4. -20~+60℃Working temperature
5. 5G vibration tested
6. High efficiency, long life span, and high reliability
Applications: Industrial automation machinery、Industrial control system、Testing and measuring instruments、Household appliances、
Led lighting appliances、Aging equipment、IT communication equipment
Warranty
3 years
Certificate
CE RoHS
Specifications
Product No. | DX-36-12 | DX-36-24 | |||||
Output | DC voltage | 12V | 24V | ||||
Rated Current | 3A | 1.5A | |||||
Current Range | 0-3A | 0-1.5A | |||||
Rated Power | 36W | 36W | |||||
Ripple and Noise(Max)Note.2 | 150mVp-p | 240mVp-p | |||||
Voltage adjustment | 10.8-13.2V | 22-27.6V | |||||
Voltage tolerance Note3 | ±1% | ±1% | |||||
Linear Regulation Note4 | ±0.5% | ±0.5% | |||||
LoadRegulationNote5 | ±0.5% | ±0.5% | |||||
Setup and rise time | 1000ms,30ms/230VAC 1000ms,30ms/110V | ||||||
Hold up time(Typ) | 50ms/230VAC10ms/115AC | ||||||
Input | Voltage range | 100-240VAC | |||||
Frequency range | 47-63HZ | ||||||
Efficiency(Typ) | 80% | 81% | |||||
AC current(Typ) | 0.73A/100V0.27A/220V | ||||||
Surge (Inrush) current (Typ) | Cold start:65A/230VAC | ||||||
Leakage Current | <2mA/240VAC | ||||||
Protection | Overload | >105% rated output power | |||||
Protection type:Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over temperature | Overheat protection starts when temperature in transistor over 140℃ | ||||||
Recovers automatically after temperature is normal. | |||||||
Environment | Working temp. | -20~+50℃(Please refer to the attenuation curve) | |||||
Working humidity | 20~90% RH,Non-condensing | ||||||
Storage temp & hmdty | -40~+80℃ | ||||||
Temp. coefficient | ±0.03%/℃(0~50℃) | ||||||
Vibration proof | 10~500HZ,5G 10min/1 cycle,period for 60min. each along X、Y、Z axes | ||||||
Safety reg. & EMC(Note.6) | Safety regulation | GB195110.1-2004/IEC61347-1:2003CE(EMC+LVD) | |||||
Voltage proof | I/P-O:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC | ||||||
Isolation resistance | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH | ||||||
EMC irradiation | EN 55022A:2006;EN61000-3-2:1995+A2:2005 | ||||||
EMC disturbance proof | EN 61000-3-2:2006; | ||||||
Others | Dimensions | 282x18x18mm(L*W*H) | |||||
Packing | 0.067kg/PCS;200PCS/13.5kg | ||||||
Remark | 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp. | ||||||
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth. | |||||||
3.Tolerance(Accuracy): including preset errors, linear adjustment rate and load adjustment rate. | |||||||
4.Linear adjustment: taken under rated load from low voltage to high voltage. | |||||||
5.Load adjustment: taken under 0~100% of rated load. | |||||||
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC. |