CNW-120-12/24
Parameter
Input voltage:176-264Vac
Output power:120W
Output voltage:12Vdc/24Vdc
Feature
1. Protection: short-circuit, overload
2. 100% full-load aged
3. Withstand 300VAC surge input for 5 seconds
4. -20~+60℃Working temperature
5. 5G vibration tested
6. High efficiency, long life span, and high reliability
Applications: Industrial automation machinery、Industrial control system、Testing and measuring instruments、Household appliances、
Led lighting appliances、Aging equipment、IT communication equipment
Warranty
2 years
Certificate CE RoHS
Specifications | |||||||
Product No. | NW-120-12 | NW-120-15 | NW-120-24 | NW-120-48 | |||
Output | DC voltage | 12V | 15V | 24V | 48V | ||
Rated Current | 10A | 8A | 5A | 2.5A | |||
Current Range | 0-10A | 0-8A | 0-5A | 0-2.5A | |||
Rated Power | 120W | 120W | 120W | 120W | |||
Ripple and Noise(Max)Note.2 | 150mVp-p | 180mVp-p | 240mVp-p | 250mVp-p | |||
Voltage adjustment | 10.8-13.2V | 13.5-16.5V | 22-27.6V | 44-52V | |||
Voltage AccuracyNote3 | ±1% | ±1% | ±1% | ±1% | |||
Linear Adjustment Note4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
Load AdjustmentNote5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
Start and rise time | 1000ms,30ms/230VAC 1000ms,30ms/110V | ||||||
Hold time(Typ) | 50ms/230VAC10ms/115AC | ||||||
Input | Voltage range | 176-264AC/250-360VDC | |||||
Frequency range | 50HZ | ||||||
Efficiency(Typ) | 80% | 81% | 82% | 82% | |||
AC current(Typ) | 1.42A/176V1.1A/220V | ||||||
Surge current (Typ) | Cold Start:65A/230VAC | ||||||
Current leak | <2mA/240VAC | ||||||
Protection | Overload | Larger than 105% of capacity | |||||
restoration after abnormity removed | |||||||
Overvoltage | |||||||
Overheat | |||||||
Environment | Working temp. | -20~+60℃(Refer to the tenuation curve) | |||||
Working humidity | 20~90% RH, without condense | ||||||
Storage temp & hmdty | -40~+80℃ | ||||||
Temp. coefficient | ±0.03%/℃(0~50℃) | ||||||
Vibration proof | 10~500HZ,5G 10min / cycle,X、Y、Z axes 60 min each | ||||||
Safety reg. & EMC(Note.6) | Safety regulation | GB195110.1-2004/IEC61347-1:2003CE(EMC+LVD) | |||||
Voltage proof | I/P-O:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC | ||||||
insulation resistance | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH | ||||||
EMC irradiation | EN 55022A:2006;EN61000-3-2:1995+A2:2005 | ||||||
EMC disturbance proof | EN 61000-3-2:2006; | ||||||
Dimensions | 160*98*42mm(L*W*H) | ||||||
Packing | 0.43kg/PCS;28PCS/14.3kg | ||||||
Notes: | 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp. | ||||||
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth. | |||||||
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate. | |||||||
4.Linear adjustment: taken under rated load from low voltage to high voltage. | |||||||
5.Load adjustment: taken under 0~100% of rated load. | |||||||
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC. |