WL-20


WL-20-12/24

Parameter

Input voltage220Vac

Output power20W

Output voltage12Vdc/24Vdc

Feature

1. Protection: short-circuit, overload

2. 100% full-load aged

3. Withstand 300VAC surge input for 5 seconds

4. -20+60℃Working temperature 

5. 5G vibration tested

6. High efficiency, long life span, and high reliability

Applications: Industrial automation machineryIndustrial control systemTesting and measuring instrumentsHousehold appliances

Led lighting appliancesAging equipmentIT communication equipment

Warranty

2 years

Certificate

CE RoHS

 

Product No.WL-20-12WL-20-24
OutputDC voltage12V24V
Rated Current1.67A0.83A
Current Range0-1.67A0-0.83A
Rated Power20W20W
Ripple and Noise(Max)Note.2150mVp-p240mVp-p
Voltage adjustment10.8-13.2V22-27.6V
Voltage AccuracyNote3±1%±1%
Linear Adjustment Note4±0.5%±0.5%
Load AdjustmentNote5±0.5%±0.5%
Start and rise time1000ms,30ms/230VAC 1000ms,30ms/110V
Hold time(Typ)50ms/230VAC10ms/115AC
InputVoltage range100-240VAC
Frequency range47-63HZ
Efficiency(Typ)80%81%
AC current(Typ)0.57A/100V0.23A/220V
Surge current (Typ)Cold start:65A/230VAC
Current leak<2mA/240VAC
ProtectionOverloadLarger than 105% of capacity
Protection type : Hiccup mode, recovers automatically after fault condition is removed
EnvironmentWorking temp.-20~+60℃(Refer to the tenuation curve)
Working humidity20~90% RH, without condense
Storage temp & hmdty-40~+80℃
Temp. coefficient±0.03%/℃(0~50℃)
Vibration proof10~500HZ,5G 10min / cycle,X、Y、Z axes 60 min each
Safety reg. & EMC(Note.6Safety regulationGB195110.1-2004/IEC61347-1:2003CE(EMC+LVD)
Voltage proofI/P-O:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
insulation resistanceI/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH
EMC irradiationEN 55022A:2006;EN61000-3-2:1995+A2:2005
EMC disturbance proofEN 61000-3-2:2006;
Dimensions138x30x19mm(L*W*H)
Packing0.074kg/PCS;150PCS/11.2kg
Notes:1. All parameters NOT specially mentinoed are measured at 230VAC input, rated load and 25℃of ambient temperature.
2.Ripple and noise are measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF and a 47 μF parallel capacitor.
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate.
4.Linear adjustment: taken under rated load from low voltage to high voltage.
5.Load adjustment: taken under 0~100% of rated load.
6. The power supply is taken as part of the whole system, and needs to be confirmed with final equipment for EMC.