SSL-120


SSL-120-12/24

Parameter

Input voltage200-220Vac

Output power:120W

Output voltage12Vdc/24Vdc

Feature

1. Protection: short-circuit, overload

2. 100% full-load aged

3. Withstand 300VAC surge input for 5 seconds

4. -20+60℃Working temperature

5. 5G vibration tested

6. High efficiency, long life span, and high reliability

Applications: Industrial automation machineryIndustrial control systemTesting and measuring instrumentsHousehold appliances

Led lighting appliancesAging equipmentIT communication equipment

Warranty

3 years

Certificate

CE RoHS


Specifications

Product No.SSL-120-12SSL-120-24

OutputDC voltage12V24V

Rated Current10A5A

Current Range0-10A0-5A

Rated Power120W120W

Ripple and Noise(Max)Note.2150mVp-p240mVp-p

Voltage adjustment10.8-13.2V22-27.6V

Voltage tolerance Note3±1%±1%

Linear Regulation Note4±0.5%±0.5%

LoadRegulationNote5±0.5%±0.5%

Setup and rise time1000ms,30ms/230VAC 1000ms,30ms/110V
Hold up time(Typ)50ms/230VAC10ms/115AC
InputVoltage range176-264AC/250-360VDC
Frequency range50HZ
Efficiency(Typ)80%82%

AC current(Typ)1.42A/176V1.1A/220V
Surge (Inrush) current (Typ)Cold start:65A/230VAC
Leakage Current<2mA/240VAC
ProtectionOverload>105% rated output power
Protection type:Hiccup mode, recovers automatically after fault condition is removed
Over temperatureOverheat protection starts when temperature in transistor over 140℃
Recovers automatically after temperature is normal.
Working temp.-20~+50℃(Please refer to the attenuation curve)
Working humidity20~90% RH,Non-condensing
EnvironmentStorage temp & hmdty-40~+80℃
Temp. coefficient±0.03%/℃(0~50℃)
Vibration proof10~500HZ,5G 10min/1 cycle,period for 60min. each along X、Y、Z axes
Safety regulationGB195110.1-2004/IEC61347-1:2003CE(EMC+LVD)
Voltage proofI/P-O:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
Safety reg. & EMC(Note.6)Isolation resistanceI/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH
EMC irradiationEN 55022A:2006;EN61000-3-2:1995+A2:2005
EMC disturbance proofEN 61000-3-2:2006;
OthersDimensions188*53*23mm(L*W*H)
Packing0.20kg/PCS;50PCS/10.3kg
Remark1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25℃environment temp.
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.
3.Tolerance(Accuracy): including preset errors, linear adjustment rate and load adjustment rate.
4.Linear adjustment: taken under rated load from low voltage to high voltage.
5.Load adjustment: taken under 0~100% of rated load.
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.