• Product NO:NW-36
    Input Voltage:90-264VAC
    Output Voltage:12,15,24,48
    Output Power:36W
    Size:85*58*38mm
DETAILS

■Features   
   
        ·International broad voltage AC input   
        ·Protection: short-circuit, overload,overheat  
        ·100% full-load aged   
        ·300VAC surge for 5 seconds withstandable  
        ·Working temperature up to 60℃   
        ·5G vibration tested   
        ·High efficiency and long life span   
        ·2 years warranty 

 

Specifications

Product No. NW-36-12 NW-36-15 NW-36-24 NW-36-48
Output DC voltage 12V 15V 24V 48V
Rated Current  3A 2.4A 1.5A 0.75A
Current Range  0-3A 0-2.4A 0-1.5A 0-0.75A
Rated Power 36W 36W 36W 36W
Ripple and Noise(Max)Note.2 150mVp-p 180mVp-p 240mVp-p 250mVp-p
Voltage adjustment 10.8-13.2V 13.5-16.5V 22-27.6V 44-52V
Voltage Accuracy  Note3 ±1% ±1% ±1% ±1%
Linear Adjustment Note4 ±0.5% ±0.5% ±0.5% ±0.5%
Load Adjustment  Note5 ±0.5% ±0.5% ±0.5% ±0.5%
Start and rise time 1000ms,30ms/230VAC 1000ms,30ms/110V
Hold timeTyp 50ms/230VAC  10ms/115AC
Input Voltage range 90-264VAC/120-370VDC
Frequency range 47-63HZ
EfficiencyTyp 80% 81% 82% 82%
AC current Typ 0.57A/90V  0.37A/220V
Surge current (Typ) Cold Start65A/230VAC
Current leak <2mA/240VAC
Protection Overload Larger than 105% of capacity
restoration after abnormity removed
Overvoltage
Overheat
Environment Working temp. -20+60(Refer to the tenuation curve)
Working humidity 2090% RH, without condense
Storage temp & hmdty -40+80
Temp. coefficient ±0.03%/ 050℃)
Vibration proof 10500HZ,5G 10min / cycleXYZ axes 60 min each
Safety reg. & EMC    (Note.6 Safety regulation GB195110.1-2004/IEC61347-1:2003  CE(EMC+LVD)
Voltage proof I/P-O/P:1.5KVAC  
insulation resistance I/P-O/P:100M Ohms/500VDC/25/70% RH
EMC irradiation EN 55015:2006;EN61000-3-2:1995+A2:2005
EMC disturbance proof EN 61000-3-2:2006;
Dimensions 85*58*38mm(L*W*H)
Packing 0.14kg/PCS;100PCS/15.3kg
Notes: 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25 environment temp.
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate.
4.Linear adjustment: taken under rated load from low voltage to high voltage.
5.Load adjustment: taken under 0~100% of rated load.
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.


Copyright 2016-2017    Shenzhen Xingzhiyou Technology Co.ltd