• Product NO:RP-60
    Input Voltage:176-264VAC
    Output Voltage:12,15,24,48
    Output Power:60W
    Size:150*110*40mm
DETAILS

 

 ■Features   
   
        ·International broad voltage AC input   
        ·Protection: short-circuit, overload,overheat  
        ·100% full-load aged   
        ·300VAC surge for 5 seconds withstandable  
        ·Working temperature up to 60℃   
        ·5G vibration tested   
        ·High efficiency and long life span   
        ·2 years warranty 

 

Specifications

Product No. RP-60-3.3 RP-60-5 RP-60-12 RP-60-15 RP-60-24 RP-60-48
Output DC voltage 3.3V 5V 12V 15V 24V 48V
Rated Current  8A 8A 5A 4A 2.5A 1.25A
Current Range  0-8A 0-8A 0-5A 0-4A 0-2.5A 0-1.25A
Rated Power 27W 40W 60W 60W 60W 60W
Ripple and Noise(Max)Note.2 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 250mVp-p
Voltage adjustment 2.9-3.3v 4.8-5.4V 10.8-13.2V 13.5-16.5V 22-27.6V 44-52V
Voltage Accuracy  Note3 ±3% ±2% ±1% ±1% ±1% ±1%
Linear Adjustment Note4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Adjustment  Note5 ±2% 1.50% ±0.5% ±0.5% ±0.5% ±0.5%
Start and rise time 1000ms,30ms/230VAC
Hold timeTyp 50ms/230VAC 
Input Voltage range 176-264VAC/260-370VDC
Frequency range 50HZ
EfficiencyTyp 70% 75% 80% 81% 82% 82%
AC current Typ 0.71A/176V  0.56A/220V
Surge current (Typ) Cold Start65A/230VAC
Current leak <2mA/240VAC
Protection Overload Larger than 105% of capacity
restoration after abnormity removed
Overvoltage
Overheat
Environment Working temp. -20+60(Refer to the tenuation curve)
Working humidity 2090% RH, without condense
Storage temp & hmdty -40+80
Temp. coefficient ±0.03%/ 050℃)
Vibration proof 10500HZ,5G 10min / cycleXYZ axes 60 min each
Safety reg. & EMC    (Note.6 Safety regulation GB195110.1-2004/IEC61347-1:2003  CE(EMC+LVD)
Voltage proof I/P-O/P:1.5KVAC  
insulation resistance I/P-O/P:100M Ohms/500VDC/25/70% RH
EMC irradiation EN 55015:2006;EN61000-3-2:1995+A2:2005
EMC disturbance proof EN 61000-3-2:2006;
Dimensions 150*110*40mm(L*W*H)
Packing 0.49kg/PCS;28PCS/14.5kg
Notes: 1. Unless specially indicated, all data are taken under 230VAC input, rated load and 25 environment temp.
2.Ripple and noise: measured with a 12” double ripple cord connected in parallel with a 0.1μF and a 47 μF capacitor on 20MHz bandwidth.
3.Accuracy: including preset errors, linear adjustment rate and load adjustment rate.
4.Linear adjustment: taken under rated load from low voltage to high voltage.
5.Load adjustment: taken under 0~100% of rated load.
6. Power supply is taken as part of the whole system, and needs to be confirmed with terminal instruments for EMC.


Copyright 2016-2017    Shenzhen Xingzhiyou Technology Co.ltd

粤ICP备16082472号